ABB 07AI91 GJR5251600R0202 Analog I/O Module

Brand: ABB Item No: 07AI91 GJR5251600R0202 Unit price:4800$ Condition: Brand new and original Quality Guarantee: 1 Year Payment : T/T and Western Union Delivery Time: 2-3 day Shipping Port: China

Products Details

Manufacture ABB
Item No 07AI91
Article number GJR5251600R0202
Series PLC AC31 Automation
Origin United States (US) Germany (DE) Spain (ES)
Dimension 209*18*225(mm)
Weight 0.9kg
Customs Tariff Number 85389091
Type I-O Module
ABB 07AI91 GJR5251600R0202 Analog I/O Module The analog input module 07 AI 91 is used as a remote module at the CS31 system bus. It has 8 analog input channels with the following features: The channels can be configured in pairs for the connection of the following temperature or voltage sensors: ± 10 V / ± 5 V / ± 500 mV / ± 50 mV 4...20 mA (with external 250 Ω resistor ) Pt100 / Pt1000 with linearization Thermocouples types J, K and S with linearization Only electrically isolated sensors may be used The range of ± 5 V can also be used for measuring 0..20 mA with an additional external 250 Ω resistor. The configuration of the input channels as well as the setting of the module address are performed with the DIL switches. The 07 AI 91 uses one module address (group number) in the word input range. Each of the 8 channels use 16 bits. The unit is powered with 24 V DC. The CS31 system bus connection is electrically isolated from the rest of the unit. The module offers a number of diagnosis functions (see chapter "Diagnosis and displays"). The diagnosis functions perform a self-calibration for all channels. Displays and operating elements on the front panel 8 green LEDs for channel selection and diagnosis, 8 green LEDs for analog value display of one channel List of diagnosis information relating to the LEDs, when used for diagnosis display Red LED for error messages Test button Configuration of input channels and setting of the module address at the CS31 bus The measuring ranges for the analog channels are set in pairs (i.e. always for two channels together) using DIL switches 1 and 2. The setting of address DIL switch determines the module address, the analog value representation and the line frequency suppression (50 Hz, 60 Hz or none). The switches are located under the slide cover on the right side of the module housing. The following figure shows the possible settings.Products Products›PLC Automation›Legacy products›AC31 and previous series›AC31 I/Os and previous series

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours